Product Description
Multitec |
Etanorm SYT |
Characteristic-Curves-Etanorm-1450
Characteristic-Curves-Etanorm-2900
Overview of technical data
Q (50Hz) : 1.5 – 740.0 (m³/h)
H (50Hz) : 2.0 – 160.0 (m)
Type of bearing : Ball bearings
Casing partition : Radially split
Drive frequency : 50 Hz /60 Hz
Type of drive : Electric motor
Drive voltage : Low voltage
Explosion protection : IP 55
No. of impeller entries : Single entry
Impeller material (EN standard) : 1.4408 / A743 GR CF8 M, CC480K-GS / B30 C90700, JL1040 / A 48 CL 35B
Type of installation : Long-coupled
Type of coupling : Direct
Type of lubrication : Grease / Oil lubrication
Max. permissible fluid temperature : 140.0 (°C)
Guaranteed to be silicon-free : Yes
Nozzle position : End suction
Maximum operating pressure : PN 16
Pull-out design : Yes
Pump set location : Dry installed
Shaft material (EN standard) : 1.4571, C45+N
Standard : EN, EN / ANSI
Suction characteristics : Non-priming
Suitable for drinking water : Yes
Type of casing : Volute casing
Type of impeller : Closed / Radial
Type of connection : Flange
UNSPSC classification : 4015150300
Casing material (EN standard) : 1.4408 / A743 GR CF8 M, CC480K-GS / B30 C90700, JL1040 / A48CL35B, JS1030 / A536 GR 60-40-18
E’class assignment : 36410000, 36410100, 36410101
Installation position : Horizontal
Shaft seal type : Mechanical seal, Gland packing
Main applications : Industry and process engineering, Water, Energy, Building services
Casing material : Cast iron, Stainless steel, Nodular cast iron, Bronze
Maximum discharge-side pressure : 16.0 (bar)
Type of installation : Stationary
Maximum speed of rotation : 3500.0 (1/min)